Brief introduction
Industrial Powerline Ethernet Bridge
Model: WD-1001M-DIN(D)
1.Product overview
DIN rail mounting industrial powerline ethernet bridge is an industrial power line communication product developed by Kunshan Wondertek Technology Co., LTD. The product supports the G.hn communication protocol standard. At present, it has been widely used in railway, mining, industrial communication, airport, subway, coal mine, intelligent storage, industrial automation control, automatic garage and other wired or sliding contact line and many other sites.
2.Product features
Packet loss:≤0.1%(100M,load 70%)
Support 7*24 hours all weather operation;
Hardware watch dog function;
Low delay communication
Wide voltage input
NDIM (Near Field Interference)
3.Product technical characteristics
3.1 Technical parameters
- support G.hn protocol standard.
- Industrial DIN standard installation or fixed installation method.
- rate adaptive.
3.2 Administrative
- Remote Firmware Update (TR069).
- 802.3D Ethernet Bridge.
- 802.1Q VLAN.
- Quality of Service(QoS) .
- IGMO(IPv4)Snooping&MLD(IPv6)Snooping
3.3 The work environment
The working temperature of the working environment is -40ºC-85ºC.
Operating environment Operating temperature :10%-85% non-condensing state Preservation humidity 5%-90% non-condensing state.
3.4 Design criteria
- ITU-T G.9960
- IEC 60529
- IEC 50022
- IEC 60068-2-6
3.5 Specification
Model |
WD-1001M-DIN-(D) |
Interface |
1*LAN 10/100/1000Base-TX self adaption RJ45,1*DC power interface |
LED display light |
Ethernet, PLC link ,Power |
Transfer frequency |
2-50MHz MIMO (based on G.9963) |
Protocol(PHY) |
IEEE802.3,IEEE802.3x, IEEE802.3u G.hn |
Security |
128-AES |
Number of each group |
Up to 8 |
installation |
Rail TS35 |
Protection level |
IP40 |
Transfer rate(PHY) |
1000Mbps |
Modulation |
OFDM |
Effective transfer rate |
TCP/IP 530Mbps |
Manageability |
802.1D Ethernet Bridge |
|
Quality of Service(QoS) |
|
IGMO(IPv4)Snooping&MLD(IPv6)Snooping |
Voltage range |
DC 10V-80V |
Operating temperature |
-40ºC-80ºC |
Size |
123*97*47(mm)(L×W×H) |
Weight |
0.25kg |
Operating environment |
Operating humidity:10%-85% (no condense) |
|
Storage humidity: 5%-90%(no condense) |
Certification |
FCC,CE class B, RoHS |
3.6 Immunity of ESD
The testing voltage which the device should be beared: ±6kV direct Discharge, ±8kV air discharge;Discharge number in Each sensitive testing point: Plus-n-Minus 10 times each;
Every time the discharge interval is 1 s.
According to B/T 17626.2-2006.
3.7Immunity of electrical fast transient impulse group(Common mode)
The testing voltage which the device should be beared:
Between the power supply voltage port and ground: ±2.0kV;
Between signal circuit and ground: ±1.0kV;
Repetition frequency: 5KHz;
Test duration: 1 min/ time;
Testing times: Plus-n-Minus 5 times each.
According to GB/T 17626.4-2008.
3.8 Anti interference of surge impact
The testing voltage which the device should be beared: ±2kV;
The interval of continuous impulses: 1min/time;
Test number: Plus-n-Minus 5 times each.
According to GB/T 17626.5-2008.(protection: all models protection and varistor series of discharge tube type)
3.9 Anti- vibration
Meet the demand of MX3 in TB1433(0-200Hz,2g acceleration, maximum amplitude 7mm), interface with no loose, device with no Sealing off and drop in the test.
4. Connection topology diagram
On-site power environment: DC+ DC- G
5. Reference for selection of PLC -Blocking -Filter
Model |
WD204series |
The rated voltage |
125/250VAC |
Working frequency |
50/60Hz |
Rated current |
10-200A |
Withstand voltage test |
1450VDC, 2sec (Line to Line) 2250VDC, 2sec(Line to Ground) |
Leakage current |
90mA Max |
Climate type |
-25ºCto+85ºC |
The standard reference |
UL1283,CSA22.2 No.8 1996,IEC/EN60939 |
Protection grade |
IP40 |
Model |
(A) Rated Current |
(≤mA) Leakage Current |
Dim. Fig. |
Output Connection |
|
|
|
|
|
|
|
WD204-10A-01 |
10 |
0.5 |
H1 |
|
|
|
WD204-20A-01 |
20 |
0.5 |
H1 |
|
|
M4 |
WD204-30A-01 |
30 |
0.5 |
H2 |
|
|
M4 |
WD204-40A-01 |
40 |
0.5 |
H2 |
|
|
M4 |
WD204-50A-01 |
50 |
0.5 |
H2 |
|
|
M4 |
WD204-60A-01 |
60 |
0.5 |
H2 |
- |
- |
M6 |
WD204-75A-01 |
75 |
0.5 |
N5 |
- |
- |
M8 |
WD204-100A-01 |
100 |
0.5 |
N5 |
- |
- |
M8 |
WD204-120A-01 |
120 |
0.5 |
N5 |
- |
- |
M8 |
WD204-50A-01 |
150 |
0.5 |
N10 |
- |
- |
M10 |
WD204-200A-01 |
200 |
0.5 |
N10 |
- |
- |
M10 |
6.The installation of PLC-Blocking Filter
All loads are installed on the Filter's Load side.
Do not connect them backwards.
7.System architecture drawing and field wiring
1,Control computer 2, switch or router 3, WD-1001M-DIN(D) 4, conductor rail/cable 5, peripheral equipment 6, PLC-blocking filter 7, load